Mammo/Tomo AEC & Uniformity Slabs
QUALITY ASSURANCE FOR MAMMOGRAPHY AND TOMOSYNTHESIS SYSTEMS
The Mammo/Tomo AEC & Uniformity Slabs are an essential tool for routine quality assurance of digital mammography and breast tomosynthesis systems. Designed to comply with the EUREF Protocol for the Quality Control of the Physical and Technical Aspects of Digital Breast Tomosynthesis Systems, it ensures reliable and consistent performance.
Manufactured from high-purity PMMA, this phantom is built for precision and durability in demanding clinical environments.
Jump To: Standards Compliance | Specifications | Accessories | Model Number | Clinical Images
Plate with Embedded Spheres:
- Used for testing Z-resolution in tomosynthesis systems
- Embedded spheres allow for the evaluation of depth resolution and system reconstruction accuracy in 3D imaging
Plate with Embedded Aluminum Foil:
- Used to assess contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR)
- High-purity (99.9%) aluminum foil serves as a contrast element to evaluate the system’s ability to differentiate between tissues of varying densities
Plain Plates:
- Used to simulate varying breast thicknesses for testing Automatic Exposure Control (AEC) accuracy and imaging performance
- Can also help assess system homogeneity and geometric distortion, ensuring consistency across different imaging conditions
RSD’s Mammo/Tomo AEC & Uniformity Slabs are a critical component for maintaining high diagnostic standards, enabling comprehensive evaluation of imaging parameters and system performance in digital mammography and tomosynthesis.
Product Features & Benefits
Automatic Exposure Control (AEC): Perform accurate checks to optimize imaging parameters
Geometric Distortion: Validate imaging system accuracy for undistorted, high-fidelity results
Signal-to-Noise Ratio (SNR): Assess image clarity and minimize noise interference
Contrast-to-Noise Ratio (CNR): Ensure optimal differentiation of subtle tissue contrasts
Homogeneity: Confirm uniform image quality across the field of view
Z-Resolution: Evaluate depth resolution for enhanced 3D imaging performance
Standards Compliance
Specifications
- One Plate: 300 mm x 240 mm x 20 mm, Embedded 10 x 10 mm Aluminum Foil
- One Plate: 300 mm x 240 mm x 5 mm, 25 Embedded Spheres, 1 mm Diameter
- One Plate: 300 mm x 240 mm x 20 mm
- One Plate: 300 mm x 240 mm x 10 mm
- One Plate: 300 mm x 240 mm x 5 mm
Accessories
- Comprehensive Product Manual
- Sturdy Carrying Case
Model Number
QA-MAM020 | Mammo/Tomo AEC & Uniformity Slabs |
---|