Micro-CT QA Phantom Set

COMPLETE PERFORMANCE ASSESSMENT FOR MICRO CT SYSTEMS

The Micro-CT QA Phantom Set is designed for the precise assessment of Micro-CT imaging systems and research applications. Its versatile design allows for comprehensive evaluations, ensuring consistent image quality and reliable diagnostic results. With customizable sizing and individual phantom availability, this kit is tailored to meet the needs of diverse Micro-CT setups.

 

The set includes a wide range of phantoms for system evaluation, and individual phantoms are also available for separate purchase:

  • CT Dose Phantom: This phantom includes a water-equivalent background and is designed to accommodate a standard pencil ionization chamber in the central bore for dose measurements.
  • Water Phantom: Pre-filled with distilled water, this phantom provides a consistent, homogeneous background for testing and calibration
  • Point Spread Function (PSF) Phantom: This phantom enables evaluation of both the Point Spread Function (PSF) and Modulation Transfer Function (MTF). It contains two wires – one positioned at the center, and another offset to assess image quality in both the central and peripheral regions.
  • Multi-Layer Phantom (Defrise): Featuring high-density disks separated by 3mm layers of low-density material, this phantom is ideal for evaluating artifacts in reconstruction algorithms.
  • Hydroxyapatite (HA) Phantom: Designed to replicate the properties of high-density bone, this phantom contains five cylindrical inserts made of varying densities of calcium hydroxyapatite (CaHA), with a water background for accurate tissue simulation.
  • Low Contrast Phantom: This phantom mimics low-density bone and comes with a water background, ideal for assessing contrast resolution in CT imaging.

The Micro-CT QA Phantom Set offers everything you need for precise and reliable Micro-CT system quality assurance, ensuring superior imaging and diagnostic accuracy.

Product Features & Benefits


 

Enhanced Imaging Performance: Enables accurate evaluation and optimization of Micro-CT systems

Versatility for Research and Clinical Use: Supports a wide range of applications in both diagnostic and research settings

Customizable Design: Standard diameter of 32mm, with options for scaling up or down to meet specific requirements

Flexible Usage: Phantoms are available individually or as a complete kit for tailored solutions

Specifications


 

  • Standard Diameter: 32 mm
  • Custom diameters available upon request

Accessories


 

  • Comprehensive Product Manual
  • Sturdy Carrying Case

Model Numbers


QA-MCT010Micro-CT QA Phantom Set
QA-MCT011CT Dose Phantom
QA-MCT012Water Phantom
QA-MCT013Point-Spread Function (PSF) Phantom
QA-MCT014Multi-Layer Phantom
QA-MCT015Hydroxyapatite (HA) Phantom
QA-MCT016Low Contrast Phantom

Clinical Images


Don’t Go Phantom. Let’s Get Started!

Complete our quote request form to have an expert RSD technician contact you with customization options and answers to any questions you may have.